3 uldp function typical examples, Uldp, Unction – QTECH QSW-3400 Инструкция по настройке User Manual

Page 84: Ypical, Xamples

Advertising
background image

+7(495) 797-3311 www.qtech.ru
Москва, Новозаводская ул., 18, стр. 1

83

8.3 ULDP Function Typical Examples

Fiber Cross Connection

In the network topology in Graph, port g1/1 and port g1/2 of SWITCH A as well as port g1/3

and port g1/4 of SWITCH B are all fiber ports. And the connection is cross connection. The

physical layer is connected and works normally, but the data link layer is abnormal. ULDP can

discover and disable this kind of error state of link. The final result is that port g1/1, g1/2 of

SWITCH A and port g1/3, g1/4 of SWITCH B are all shut down by ULDP. Only when the
connection is correct, can the ports work normally (won’t be shut down).
Switch A configuration sequence:
SwitchA(config)#uldp enable
SwitchA(config)#interface ethernet 1/1
SwitchA(Config-If-Ethernet1/1)#uldp enable
SwitchA(Config-If-Ethernet1/1)#exit
SwitchA(config)#interface ethernet 1/2
SwitchA(Config-If-Ethernet1/2)#uldp enable
Switch B configuration sequence:
SwitchB(config)#uldp enable
SwitchB(config)#interface ethernet1/3
SwitchB(Config-If-Ethernet1/3)#uldp enable
SwitchB(Config-If-Ethernet1/3)#exit
SwitchB(config)#interface ethernet 1/4
SwitchB(Config-If-Ethernet1/4)#uldp enable

As a result, port g1/1, g1/2 of SWITCH A are all shut down by ULDP, and there is notification

information on the CRT terminal of PC1.
%Oct 29 11:09:50 2007 A unidirectional link is detected! Port

g1/2

Switch B

g1/4

g1/3

g1/1

PC1

PC2

Advertising