P

For Angle Control operations, the Torque value may reach a peak value and then drop to a lower

value as the fastener is stretched beyond the point of yielding. Final Torque High and Low Limits are
either set by the engineering specification for that specific fastener, or by determining the acceptable
limits from a study of known good and bad assemblies.



ANGLE CONTROL

REJECT TYPE

CAUSES

FINAL TORQUE HIGH LIMIT

Reduced joint compression.
Increased joint friction.
Excessive chatter of the torque signal due to slip stick friction.
Incorrect parameter set-up.

FINAL TORQUE LOW LIMIT

Increased joint compression.
Reduced joint friction.
Excessive yield of fastener.
High initial prevailing torque.
Incorrect parameter set-up.
Reject condition caused by another monitor item reject.

Peak Torque High Limit

Peak Torque Low Limit

Torque

Angle/Time

Final Torque High Limit

Final Torque Low Limit

Snug Torque

Threshold Torque

Speed Change Torque

1

st

Torque

Crossover Torque

Final Time

1

st

Time

Standard

Angle

Advertising