AFC1500 Operations Manual

Chapter 8: Maintenance and Inspection (Rev. 6: 10/09)

Page 8-9

8.3

Replacements

WARNING:

DO NOT CONNECT OR DISCONNECT CABLES OR OTHER SYSTEM

COMPONENTS WITH POWER APPLIED. FOLLOW LOCKOUT/TAGOUT AND OTHER
APPLICABLE SAFETY PRECAUTIONS.

NOTE:
When replacing the AFC1500 System SAN unit, ensure that the new unit is configured with
the compatible Hardware and Firmware version as the unit being replaced.. The Firmware Version
number will show in the Data Display when the Parameter number displays 00 and the D-NO displays
01.
Newer firmware versions will provide compatibility with older firmware versions under most instances.
When the system requires special firmware due to customer requirements, care should be taken to
ensure Spare units are ordered with the Firmware version identified.

8.3.1 SAN Unit Replacement (No Partial Replacement - Complete Unit Only)

When one SAN unit is being replaced with another, it is important to verify that both Units are
compatible Types. (Refer to Section 2.4.1 SAN unit and to the chart, below.)

TOOL TYPE

ORIGINAL SERVO

TYPE

UPDATED SERVO

TYPE

NFT-051RM1(A) –S1

SAN2-12

SAN3-24

NFT-051RM1(A) -S

SAN2-12

SAN3-24

NFT-101RM1(A) –S/O

SAN2-12

SAN3-24

NFT-201RM1(A) –S/O

SAN2-12

SAN3-24

NFT-211RH1(A/B) -SA

N/A

SAN3-24H

NFT-301RM2(A) –S/O

SAN2-24

SAN3-24

NFT-311RH1(A/B) -SA

N/A

SAN3-24H

NFT-401RM1(A) –S/O

SAN2-12

SAN3-24

NFT-411RH1(A/B) -SA

N/A

SAN3-24H

NFT-401RM3(A) –S/O

SAN2-40

SAN3-40

NFT-601RM3(A) –S/O

SAN2-40

SAN3-40

NFT-801RM3(A) –S/O

SAN2-40

SAN3-40

NFT-801RH3(A/B) -SS

N/A

SAN3-60H

NFT-132RM3(A) –S/O

SAN2-40

SAN3-40

NFT-132RH3(A/B) -SS

N/A

SAN3-60H

NFT-152RM3(A) –S/O

SAN2-40

SAN3-40

NFT-202RM3(A) –S/O

SAN2-40

SAN3-40

NFT-202RH3(A/B) -SS

N/A

SAN3-60H

NFT-302RM3(A) –S/O

SAN2-40

SAN3-40

NFT-502RM4(A) –S/O

SAN2-80

SAN3-120TM

NFT-802RM4(A) –S/O

SAN2-80

SAN3-120TM

NFT-103RM5 –S

SAN2-120

SAN3-120WM

1. Verify the enclosure power is off. Ensure all cables connected to the front of the SAN unit are
clearly marked (for reconnection).

2. Disconnect all cables from the front of the unit.

3. Loosen (do not remove) the three (3) screws that secure the SAN unit to the back panel. The up-
per bracket of the SAN unit has one slotted hole, and the bottom bracket has two open-ended slots.

4. Lift up and out on the SAN unit to remove.

5. Verify the new SAN unit dip switches are set to the appropriate spindle number and ramp-up time
(as the unit being replaced). Refer to Section 4.10.

6. Verify the SAN Units have the same configuration (hardware and software).

7. Install the new SAN unit in reverse order of removal.

8. Apply power to the enclosure. After approximately 7 seconds, the System will finalize the Power
On Self Test (POST).

9. The SAN unit WILL require reentry of the preset data. Refer to Chapters 6 and 7.