2 component dimensions, 1 san controller unit dimensions – FEC AFC1500 User Manual

Page 47

Advertising
background image

FEC AFC1500 Operations Manual Chapter 4: System Setup and Wiring (Rev. 6.1: 8/12)

Page 4-3

4.2

Component Dimensions

The specifications for all of the AFC1500 standard system equipment is outlined in this Chap-
ter to aid in determining space, mounting & wiring requirements.

4.2.1 SAN Controller Unit Dimensions

FIG. 4-2-1 SAN Controller unit Dimensions

Unit

A

B

C

D

Weight

SAN2-12

255

60

40

0

1.4 Kg

SAN2-24/40
SAN3-24/40

SAN3-24H
SAN3-60H

255

60

40

14

1.8 Kg

SAN2-80

SAN3-120TW

255

90

60

14.5

3.1 Kg

SAN2-120

SAN3-120WM

255

90

60

33.5

3.6 Kg

Note: Dimensions shown in millimeters.

Screw slot is 5mm width.


The Unit(s) must be mounted with a minimum clearance of 13 mm on each side to allow for
proper heat dissipation. Cable connections on the front of the Units require 100 mm of
clearance.

SAN Units must be located at a minimum 300 mm from any high transient voltage power
source. High transient sources such as relays, AC contactors, AC motor drives, etc. may
cause malfunction of the AFC1500 SAN unit.

All motor cables and I/O cables must be run separate from all high transient voltage sources.

When locating inside an enclosure, avoid mounting at or near the top where internal enclo-
sure heat is most extreme.

HEAT SINK

(SAN40/80 ONLY)

265.00 [10.43]

B

D

C

A

235.00 [9.25]

159.50 [6.28]

MOTOR

AC 200-230V

PLC

T/D

RESOLVER

MON.

ACC.

RUN

485

RS

REJ.

BYPASS

ABN.

BUSY

SV.

SW1

POWER

CON1

Advertising