FEC AFC1500 User Manual

Page 96

Advertising
background image

Chapter 6: Fastening Instructions

Page 6-10

{

Three-Step Fastening

P

Three-step fastening will be used primarily for joints that have a requirement to synchronize with

another spindle during the incremental stages of the rundown to crush/compress a gasket or grom-
met or for special joint conditioning (valve cover, oil pan, or body assembly, for example).


1. Angle control commences at SNUG TORQUE. All angle values are referenced from this point.

2. Once SPEED CHANGE TORQUE is reached or FREERUN REVOLUTIONS expires, the system will

switch from FREERUN SPEED to SLOWDOWN SPEED and continue to fasten to 1ST
TORQUE/ANGLE.

3. The system will fasten to the 1ST TORQUE/ANGLE value during the specified 1ST TIME. 1ST

TORQUE/ANGLE must be reached within the 1ST TIME limits or a reject will occur.

4. Upon reaching 1ST TORQUE/ANGLE, 1ST TIME ends and FINAL TIME begins. 1ST

TORQUE/ANGLE is the shift point to TORQUE SPEED and the synchronization point prior to com-
mencing the next step.

(See 4.7.6 for Standalone Sync. info)

.

5.

The system will fasten to CROSSOVER TORQUE/ANGLE, synchronize with other spindles
and then fasten to STANDARD ANGLE using TORQUE SPEED during FINAL TIME.
STANDARD ANGLE must be reached within the FINAL TIME limits or a reject will occur.


NOTE: When performing multiple step Angle control fastening, the rotation Angle should be
performed as one continuous operation. There should be no intermediate stop / synchroniza-
tion points once Snug Torque has been sensed and rotation angle is being controlled. Under
special conditions multiple steps can be performed using intermediate Torque or Angle
stop/synchronization points.



FUNCTION

RECOMMENDATION / COMMENT

SPEED CHANGE TORQUE

30% of SNUG TORQUE

THRESHOLD TORQUE

Start point of 1

st

torque rate monitoring (section 6.2)

1ST TORQUE/ANGLE

80% of SNUG TORQUE
Used for RATE/TIME settings and TORQUE SPEED initiation.

SNUG TORQUE

Angle Control Start Point

CROSSOVER
TORQUE/ANGLE

Start point of 3

RD

torque rate monitoring (section 6.2)

Synchronization point for 3rd Step

STANDARD ANGLE

Engineered product fastening specification

1ST TIME HIGH/LOW LIMIT

Acceptance range to reach 1ST TORQUE/ANGLE setting

FINAL TIME HIGH/LOW LIMIT

Acceptance range to go from 1ST TORQUE/ANGLE to
STANDARD ANGLE












Advertising