FEC AFC1500 User Manual

Page 131

Advertising
background image

AFC1500 Operations Manual

Chapter 7: System Operations (Rev. 6.1: 1/13)

Page 7-17

Data No.1B Breakaway Torque Limit [Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1
When this torque is exceeded during Reverse 2 or 3 operations, an Abnormal will be
generated that will stop the operation.

Data No.1C Final Low Torque [Nm, Kgm...]
Data No.1D Final High Torque
[Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1
For [Angle Method], sets the High and Low limits for Torque at the point that the final Fastening Angle
is achieved.
For [Torque Method], during Torque Recovery, sets the High and Low limits for Torque at the
point that the final Fastening is completed.

Data No.1E 2ND Rate Start Torque [Nm, Kgm...]

Setting range: 0 ~ [10: Cal torque] × 1.0
Start point for 2

nd

Torque rate monitoring [Crossover is the end]















Data No.26 2ND Rate Start Angle [deg] (NOT USED as standard function)

Setting range: 0 ~ 9999 degrees
Start point for 2

nd

Torque rate monitoring [CROS Torque/Angle is the end]















Torque

Angle

26 2ND

24 CROS

32 Rate 2 Low Limit

33 Rate 2 High Limit

Angle

18 CROS

1E 2ND

32 Rate 2 Low Limit

33 Rate 2 High Limit

Torque

If 2nd Torque Rate monitoring is not required, [1E:2

nd

Rate Start Torque] should be set

the same or higher than [10: Calibration Torque]

Advertising