7.3.7 I/O Enable (Stand-Alone or Multi Configuration)

Since the I/O of the SAN Unit can be controlled either as a stand alone unit or part of a multi-
ple spindle configuration controlled by the Multi Unit, the I/O needs to be configured for the
particular application. The stand alone unit is controlled from the I/O on the SAN unit using
the PLC I/O connector. Using a Multi Unit, the SAN PLC I/O connector is disabled and all
I/O is controlled from the Multi Unit. (Some I/O remains active in the SAN unit even with a
Multi Unit. See 4.7.1)
It is important to remember that the main difference between using a stand-alone unit or a
Multi Unit configuration is that with a Multi Unit, ALL spindle sequencing is controlled by the
system, whereas with a stand - alone unit the sequence must be performed by the PLC. This
means that for a stand alone unit any type of spindle grouping, reverse operations, timing is-
sues or multiple fastenings must be programmed in PLC logic. Also, using a Multi Unit,
Fieldbus interfaces are available for many types open architecture I/O systems.

From Power on;
1. Depress MODE Button to get to the Parameter Display Mode. (in BYPASS mode)
2. Depress MODE button two more times until blinking cursor is in the rightmost digit.
3. Depress the [

] key until the [D-

NO] is “03”, this is the Fastening Function Version.

4. Verify the data in the upper data display is the version required.
(1.27 = Stand Alone Unit PLC I/O, 1.03 = Multi Unit PLC I/O, 1.23 Dual Transducer Mode)
5. To make a change, Depress [SET]
6. The cursor will blink on the leftmost digit.
7. Using the [

] and [

] buttons, enter 1827 for version 1.27, 1803 for version 1.03 or 1823 for

1.23.
(use the MODE button to move to the next digit)
8. Depress the [SET] button to enter the change.
9. CHNG - NO will appear in the display, use the [

] and [

] buttons to change the NO to YES,

then press [SET] to confirm and enter the change.
10. (switch back in RUN mode) Cycle power OFF / ON to the unit.

FIG. 7.3.7 I/O Enable Stand Alone / Multi Selection.

ROM VERSION

FASTENING FUNCTION VERSION

AMPLIFIER VERSION

TORQUE UNIT (0 = Nm)

1.27 = STAND ALONE UNIT
1.03 = MULTI UNIT CONFIG.