FEC AFC1500 User Manual

Page 128

Advertising
background image

Chapter 7: System Operations

Page 7-14

Data No.11 Peak Torque Low Limit [Nm, Kgm...]
Data No.12 Peak Torque High Limit
Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1
Setting points for the High and Low limits of the Peak Fastening Torque. If the High or Low limits are
exceeded the operation is rejected.

Data No.13 Standard Torque [Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0
Set point of the Fastening Standard (Target) Torque. This function is only available when Torque
method is selected for [00: Fastening Mode].

Data No.14 Speed Change Torque [Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.0
Set the torque value that switches Freerun speed to Slowdown speed.


























Data No.15 1ST Torque [Nm, Kgm...] Setting range: 0 ~ [10: Calibration torque] × 1.0
Data No.23 1ST Angle
[deg] Setting range: 0 ~ 9999

1

ST

stop / synchronization point for multiple step fastening operations.

End point for 1

st

torque rate calculation. [17: Threshold Torque is beginning]

Shift point for changing to Torque Speed [53: Torque Speed]
End of 1

st

Time and beginning of Final Time


Even if Freerun Revolutions are not achieved, the speed will change to
Slow Down Speed when Speed Change Torque is detected.

SPEED

60 Freerun Revolutions

51 Freerun
Speed

40 Initial Time

14 Speed Change Torque

52 Slowdown Speed

53 Torque Speed

54 Reverse Speed

50 Initial Speed

63 Reverse Revolutions

Fastening

Advertising