7.3.5 Data Edit mode operation.






Depressing the [MODE] button will bring up the
setup mode from download mode. Both [PARM]
display digits will appear blinking, specifying the
cursor position. Use the [

] and [

] buttons to

select the desired parameter number.

Depressing the [MODE] key again will bring the
blinking cursor to the first digit in the [D-NO] field
and depressing it again will bring it to the last
digit of the field. Use the [

] and [

] buttons to

select the desired [D-NO] number which is to be
edited.

After you have selected the Parameter number
and the Data number you would like to edit,
press the [SET] button to enter the Data Edit
mode.

The blinking digit will now appear at the left digit
of the DATA field. You can move one digit to
the right each time you press the [MODE] but-
ton. By pressing the button four times, you
leave the Data Edit mode and return to the Set-
up mode (without saving any changes). Use the
[

] and [

] buttons to increase or decrease the

digit that is blinking.

After changes have been made, pressing the
[SET] button will save the changes and exit to
the Setup mode.

If the entered values are out of range / limits,
"Err" will appear, and the new data will be ig-
nored. In this case, return to the parameter
number selection (using the [MODE] key) and
enter data that is acceptable.


FIG. 7-3-3 Setup mode operation


When the Torque Unit number (PARM 0 D-NO 00) or the Tool Type (PARM 0 D-NO 20) is
changed, the [DATA] display will show "CHNG," and the D-NO display will show "NO." Use
the vertical arrow buttons to choose YES or NO; YES means that the data will be entered if
the confirmation SET button is pressed. The [SET] and [MODE] buttons will have no effect
when "NO" appears. If no button is pushed within five seconds, the new data will be ignored,
and the system will exit the Data Edit mode. After confirming the new data, toggle the
Run/Bypass switch for data to be set.

Warning:

When the Torque Unit (PARM 0, and D-NO 00) or the Tool Type (PARM 0, and D-No

20) is changed, all torque settings (D-No 00-1E) and speed settings (D-No 50-56) will be
cleared.