Chapter 4: System Setup and Wiring

Page 4-14

PIN NUMBER

DESCRIPTION

SAN2-12M~

SAN3-120TM

SAN3-120WM

4

5

200~220 VAC, 50/60Hz, 3-Phase (U) Red

3

4

200~220 VAC, 50/60Hz, 3-Phase (V) White

2

3

200~220 VAC, 50/60Hz, 3-Phase (W) Black

2

Not Connected

1

1

FRAME GROUND

Green

Recommended conductor size = 16 AWG (for all units)

CAUTION: If the equipment is powered on and off repeatedly, internal circuit protec-
tion devices may trip due to high in-rush current overload. It may take up to five
minutes of “off” time to clear the self-protection circuit.

4.6.2. Calculating Circuit Protection


WARNING: Follow Lockout/Tagout and other safety precautions when connecting and/or dis-
connecting cabling, wiring, and equipment.

















The chart above shows nominal motor ratings for standard motors, along with the power re-
quirements (KVA) for each spindle. (These already have a safety factor calculated in)
Use the formula below to compute transformer secondary fuse or circuit breaker sizing:


Example:



*
Use a fuse or circuit breaker with next available highest rating. Due to the high inrush cur-
rent at power up, it is recommended to use SLOW BLOW type fuses or fuses rated for motor
loads such as Bussman

® FRS/FRN type.

1.5 X

TRANSFORMER (VA)

SECONDARY VOLTAGE

.

.

3

= SECONDARY FUSE SIZE

1.5 X

1000 (VA)

200 VAC

.

.

3

= 4.3 AMP (USE 5 AMP FUSES)*

RATED VALUES FOR CALCULATING CIRCUIT PROTECTION

MOTOR TYPE

MOTOR

WATTAGE

# OF SPINDLES

PER 1 KVA

KVA PER

SPINDLE

RM1

60

10 SPINDLES

.100 KVA

RM2 / RH1

80 / 70

8 SPINDLES

.125 KVA

RM3

200

6 SPINDLES

.166 KVA

RM4 / RH3

1500 / 200

3 SPINDLES

.333 KVA

RM5

3000

1.5 SPINDLES

.666 KVA