FEC AFC1500 User Manual

Page 71

Advertising
background image

FEC AFC1500 Operations Manual

Chapter 4: System Setup and Wiring (Rev. 6:10/09)

Page 4-27

B. Fastening Work Selection and START signal input


WORK SELECT Inputs provide a means to change the preset parameter sets when the system uses
multiple fastening specifications. These four bits are used in a binary fashion to select up to 16 dif-
ferent parameter sets.

With none of the bits enabled, the system will automatically use parameter set #1. See 4.7.2 for the
WORK SELECT truth table. FEC recommends the confirmation of the proper WORK SELECT pri-
or to initiating a START input. This can be done by monitoring the Work Select output signals prior
to enabling the start signal. (See 4.7.3 Bank Select Table for BANK 2)







FIG. 4-7-7b Example of Parameter # 6 Selection

WORK SELECT 0

WORK SELECT 1

WORK SELECT 2

WORK SELECT 3

BANK SELECT 0

BANK SELECT 1

START

ON

OFF

OFF

ON

OFF

OFF

PIN 14

PIN 15

PIN 16

PIN 9

PIN 13

PIN 12

PIN 4

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

PIN 22

WORK SELECT 3

PIN 19

PIN 20

WORK SELECT 2

WORK SELECT 1

PIN 21

WORK SELECT 0

ON

OFF

ALLOW 5msec AFTER
PARAMETER SELECTION
VERIFICATION BEFORE
APPLYING THE START
INPUT SIGNAL.

TO VERIFY A PARAMETER
SELECTION IS ACTIVE,

SELECT DATA BANK 2.
THEN AFTER 5 msec
READ THE WORK SELECT
OUTPUT SIGNALS.
REFERENCE TABLE 4.73

TO SELECT A PARAMETER
ACTIVATE THE WORK
SELECT INPUT SIGNALS.

REFERENCE TABLE 4.7.2