7.2.2 Real-time display indication mode.

While the Real Time Display mode is activethe [D-NO] displays 0 ~ 5. You can choose the
desired type of data by pressing the [

] and [

] keys to change the [D-NO] (data number).

The indicator will display the following data in the "DATA" area for the selected D-No. The
PARM data will remain showing the parameter number.

D-No

DATA

0

Torque value.

1

Torque voltage.

2

Peak Torque (maximum hold).

3

Rotated Angle.

4~5

Factory settings





Torque value:
The real-time torque value from
the torque transducer is displayed.


Torque voltage:
The real-time torque signal
voltage from the torque transducer is dis-
played.


Peak torque:
The peak torque, measured
since the last time the display mode was
switched to Real Time Display Mode. (This is
reset when the display mode is changed from
the Real Time Display Mode.)

NOTE:
Motor Lock Function
When [SET] is depressed during this display,
the motor is locked for up to one minute allow-
ing the spindle to be checked with a torque
wrench while displaying the reaction torque.
Press RESET to unlock the Motor before one
minute has expired. WARNING: Do not repeat
this procedure repetitively or the motor will
overheat.


Angle (rotation):
The real-time angle of rota-
tion of the tool output shaft (in the

fas-

tening direction CW), measured since the last
time the display mode was switched to Real

Time Display Mode. (-1999

to 9999

).


Button operation during the real-time mode is
indicated in Fig. 7-2-2.



FIG. 7-2-2 Real time display selection