AFC1500 Operations Manual

Chapter 9: Troubleshooting (Rev. 6: 10/09)

Page 9-3

9.2

Torque Transducer Origin Error, Cal Check Error.

9.2.1

Code 1-0 TORQUE TRANSDUCER / ZERO VOLTAGE ERROR

Zero level does not match master level read from tool EEPROM during power on initializa-
tion.

This abnormal is caused from;
1. When the tool transducer is sensing excessive torque due to pressure on the tool body.
2. If the controller or the transducer cable is located in an electric or magnetic noise field.
3. When the torque transducer, transducer (T/D) cable or the controller malfunctions.

RECOVERY:
1. Check that the tool has no external force applied to it. (Nothing touching the tool assembly)
2. Verify that the cables or controllers are not located near any high voltage transient power
sources. Relocate as required and reinitialize.
3. Exchange transducer (T/D) cable, tool and/or controller with known working units. Reini-
tialize the system after each exchange, and make note of any change in the location of the
abnormal.
4. Replace the defective component.

9.2.2

Code 1-1 TORQUE TRANSDUCER / CAL VOLTAGE ERROR

Calibration voltage error during power on initialization.

This abnormal is caused from;
1. When the tool transducer is sensing excessive torque due to pressure on the tool body.
2. If the controller or the transducer cable is located in an electric or magnetic noise field.
3. When the torque transducer, transducer (T/D) cable or the controller malfunctions.

RECOVERY:
1. Check that the tool has no external force applied to it. (Nothing touching the tool assembly)
2. Verify that the cable or controller is not located near any high voltage transient power
sources. Relocate as required and reinitialize.
3. Exchange transducer (T/D) cable, tool and/or controller with known working units. Reini-
tialize the system after each exchange, and make note of any change in the location of the
abnormal.
4. Replace the defective component.

9.2.3

Code 1-2 TORQUE TRANSDUCER / ZERO CHECK ERROR

Zero level voltage loaded to memory from tool EEPROM during initialization does not match
the actual zero level during a self check with the self check function DISABLED.

This abnormal is caused from;
1. When the tool transducer is sensing excessive torque due to pressure or vibration during
the fastening cycle start.
2. If the controller or the transducer cable is located in an electric or magnetic noise field.
3. When the torque transducer, transducer (T/D) cable or the controller malfunctions.

RECOVERY:
1. Check that the tool has no external force applied to it.
2. Verify the tool mounting bolts are tight and nothing is cause excessive vibration to the tool.
3. Verify that the cables or controllers are not located near any high voltage transient power
sources. Relocate as required and attempt again the fastening start input.
4. Exchange transducer (T/D) cable, tool and/or controller with known working units. Apply
start signal after exchange, and make note of any change in the location of the abnormal.
5. Replace the defective component.