Chapter 2: Specifications

Page 2-4

2.3

SAN Unit Specifications

ORIGINAL SAN UNIT TYPE

SAN2 - 12

SAN2 - 24

SAN2 - 40

SAN2 - 80

SAN2 – 120

TOOL MOTOR TYPE

RM1

RM2

RM3

RM4

RM5

TOOL MAX. TORQUE

4.0 Kgfm

(39Nm)

4.0 Kgfm

(39Nm)

30.0 Kgfm

(294Nm)

80.0 Kgfm

(784Nm)

500 Kgfm

(4093Nm)

MOTOR MAX. POWER

60W

80W

200W

1500W

3000W

MOTOR RATED CURRENT

1A (RMS)

2A (RMS)

3A (RMS)

11A (RMS)

21A (RMS)

SAN INPUT POWER

180-242VAC 50/60Hz

SAN IDLE POWER
CONSUMPTION (watt/hour)

18wh IDLE

SAN AVERAGE POWER
CONSUMPTION (watt/hour)*

25wh

43wh

95wh

134wh

SAN MAX. MOMENTARY

CURRENT (Inrush)

9.5A

18A

38.6A

79.2A

116.2A

SAN UNIT OUTPUT POWER

270-300VAC PWM

UPDATED SAN UNIT TYPE

SAN3 - 24

SAN3 –

24HM

SAN3 - 40

SAN3 –

60HM

SAN3 –

120TM

SAN3 –
120WM

TOOL MOTOR TYPE

RM1

RM2

RH1

RM3

RH3

RM4

RM5

TOOL MAX. TORQUE

4.0 Kgfm

(39Nm)

30.0 Kgfm

(294Nm)

(200Nm)

80.0 Kgfm

(784Nm)

500 Kgfm

(4093Nm)

MOTOR MAX. POWER

60W

80W

70W

200W

1500W

3000W

MOTOR RATED CURRENT

1A (RMS)

2A (RMS)

2A (RMS)

3A (RMS)

6A (RMS)

11A (RMS)

21A (RMS)

SAN INPUT POWER

180-242VAC 50/60Hz

SAN IDLE POWER

CONSUMPTION (watt/hour)

18wh IDLE

SAN AVERAGE POWER
CONSUMPTION (watt/hour)*

25wh

43wh

112wh

95wh

134wh

SAN MAX. MOMENTARY

CURRENT (Inrush)

9.5A

18A

19A

38.6A

53.7A

79.2A

116.2A

SAN UNIT OUTPUT POWER

270-300VAC PWM

*

Watt hours measured using the SAN unit at 60% duty/95% torque capacity


CAUTION:
If the equipment is powered on and off repeatedly, internal circuit protec-
tion devices may trip due to high in-rush current overload. It may take up to five mi-
nutes of “off” time to clear the self-protection circuit.

{

{

{

{

Controller Processor:

32-bit RISC (Reduced Instruction Set CPU)

{

Parameter / Firmware Storage:

Flash ROM

{

Fastening Method:

Torque, Angle and Current Control Method

{

Torque Rate Calculation:

3 ranges

{

{

{

{

Data Communications:

(2) - RS485 communication ports: (1) for AFC User

Console Software and (1) for Multi Unit Communications