FEC AFC1500 Operations Manual

Chapter 4: System Setup and Wiring (Rev. 6:10/09)

Page 4-29

4.9 MON. Connector - External Torque/Angle/Current/Speed OUTPUT

This auxiliary connector is used to output Torque, Angle, Current & Speed signals to external
equipment for monitoring purposes (X-Y Plotter, etc). The signals output from this con-
nector are the same signals that the system receives during the fastening process. This
connection is not required for the system to operate.

FIG. 4-9a MON connector


Mating Connector: Molex #39-01-2065 Pin # 30-00-0047

PIN

Signal

Description

1

Torque voltage

Torque voltage monitoring output. (-5V to +5V).(2.5V full
scale shift)

2

Angle pulse

Angle pulses monitoring output (TTL, IOL = 30 ma).

3

Angle CW/CCW

Forward/Reverse pulse monitoring output (TTL, IOL = 30
ma).

4

Current voltage

Current voltage monitoring output (1.2Apeak/V).

5

Speed voltage

Speed voltage monitoring output (1000rpm/V [motor speed]).

6

Signal ground

Common for all output signal.

IOL = Current Output Low

Angle and direction are output as shown below.

FIG. 4-9b T/A OUT signal reference

6

3

5

4

2

1

CW/CCW

PULSES

ANGLE

ROTATION

TOOL

STOP

CW

CCW