Warning – FEC AFC1500 User Manual

Page 168

Advertising
background image

Chapter 9: Troubleshooting

Page 9-14

9.10.7 Code 9-6

PARAMETER ERROR / ANGLE SETUP ERROR

One of the Angle presets is out of range

RECOVERY:
1. Verify that the Angle presets are in range for the tool size.
2. Check that the Angle presets are not <0> or setup as specified in 6.1.2.

9.10.8 Code 9-7

PARAMETER ERROR / REVERSE TORQUE OVER.

The Reverse torque is more than 1.5 times the Full Scale Torque.

RECOVERY:
1. Verify that the preset value is correct.
2. If the value is correct, check the application. The size of the tool is not adequate for this
application or the fastener being reversed may be over-torqued.


WARNING:

DO NOT CONNECT OR DISCONNECT CABLES OR OTHER SYSTEM

COMPONENTS WITH POWER APPLIED.

Advertising