4 point-to-point torque rate monitoring – FEC AFC1500 User Manual

Page 104

Advertising
background image

Chapter 6: Fastening Instructions

Page 6-18

6.2.4 Point-to-Point Torque Rate Monitoring

The AFC1500 System is capable of performing 3 torque rate calculations. The Point-to-Point torque
rate method performs the calculation based upon completing a step of the process, and then calculat-
ing the rate for the full duration of that step. The chart below identifies the different areas that torque
rate can be calculated. Each Torque Rate is calculated by dividing the change in torque during the
specific period by the change in angle.

Example: 25Nm / 100deg. = 0.25 Nm/Deg. (rate)

NOTE: Setting any of the Torque Rate START POINTS above the FASTENING
END TORQUE will eliminate the torque rate calculation for that stage.


Torque Rate Calculation Areas (Typical for 1 or 2 step)
(CROSSOVER TORQUE set above FASTENING END TORQUE)
Refer to Fig. 6-2-4a

STAGE

START POINT

STOP POINT

1ST TORQUE RATE

THRESHOLD TORQUE

1ST TORQUE

2ND TORQUE RATE

2ND RATE START TORQUE

FASTENING END

Torque Rate Calculation Areas (Typical for 3 step, however can be used on 1 or 2 step)
Refer to Fig. 6-2-4b

STAGE

START POINT

STOP POINT

1ST TORQUE RATE

THRESHOLD TORQUE

1ST TORQUE

2ND TORQUE RATE

2ND RATE START TORQUE

CROSSOVER TORQUE

3RD TORQUE RATE

CROSSOVER TORQUE

FASTENING END

In the case that Torque Rate Stop Points are not set incrementally larger from THRESHOLD
to 2

ND

RATE START TORQUE and then to CROSSOVER TORQUE, the rate calculation will

be performed at the next successive available stop point prior to Fastening end.

STAGE

START POINT

AVAILABLE STOP POINTS

1ST TORQUE RATE

THRESHOLD

1ST TORQUE
CROSSOVER TORQUE
FASTENING END

2ND TORQUE RATE

2ND RATE START

CROSSOVER TORQUE
FASTENING END

3RD TORQUE RATE

CROSSOVER TORQUE

FASTENING END

For all control operations, the High and Low Torque Rate limits are set by determining the
acceptable limits from a study of known good and bad assemblies.

NOTE: Refer to table above for stand alone SAN Unit Start/Stop points.