3 fastening results display mode – FEC AFC1500 User Manual

Page 120

Advertising
background image

Chapter 7: System Operations

Page 7-6

7.2.3 Fastening Results Display Mode.

In Fastening Results Display mode (when [D-NO] shows _0 ~



), data can be obtained by

pressing the [

] and [

] keys to scroll the [D-NO] until the desired DATA item is displayed.

The following information will be displayed in the [DATA] display section for the displayed
[D-NO]:

D-NO

DATA

Unit *

_0

Peak Torque Value (Judgment torque value)

Nm

_1

Final Angle Value

deg

_2

1ST Torque Rate Value

Nm/deg

_3

2ND Torque Rate Value

Nm/deg

_4

1ST Area Fastening Time

Sec

_5

Final Area Fastening Time

Sec

_6

Cycle Time

Sec

_7

Fastening Mode No.

_8

3RD Torque Rate Value

Nm/deg

_9

Not Used

0

Fastening Method No.

=1

Step

=2

Not Used

=3

Self Check ON: Checked OFF: Unchecked

=4

Reverse Flag ON: Reversed OFF: Not reversed

=5

Cause of Fastening stop 0: Reset / No data / After reverse
1: Abnormal 2: BYPASS signal 3: Stop signal
4: REJECT 5: ACCEPT (Normal)

=6

Torque Judgment tq H/L (Final) H/L (Peak)

=7

Angle Judgment An H/L (Angle)

=8

Torque Rate Judgment r H/L (1ST) H/L (2ND) H/L (3RD)

=9

Time Judgment ti H/L (1ST) H/L (FNL) /
r (left) = Low rundown rev

– r (right) = High rundown rev

0

1ST Torque Rate Area Increment Torque

Nm

1

2ND Torque Rate Area Increment Torque

Nm

2

Offset Torque

Nm

3

1ST Peak Torque

Nm

4

Final Torque Value

Nm

5

Angle at Peak Torque (Judgment Torque)

deg

6

Maximum Current Value

A



Not Used

Unit of measure for Torque can be Nm, Kgm, Kgcm, Ftlb or Inlb

FIG. 7-2-3 Fastening results display selection