AFC1500 Operations Manual

Chapter 7: System Operations (Rev. 6.1: 1/13)

Page 7-21

Data No.70 Full Scale Current [A]
Data No.71 High Current Limit
[A]
Data No.72 Low Current Limit [A]
Data No.73 Fastening Current Limit [A]

Setting range: 0 ~ Due to unit type
Set the values below according to the unit type that will be used.
Used as a redundant check of the fastening process. Please contact FEC Inc. for assistance.


Unit Type

Tool Type

Full Scale Cur-

rent [A]

High Current

Limit [A]

Low Current Lim-

it [A]

Controlled Cur-

rent [A]

SAN3-24M

NFT -

□□□RM1

12.0

12.0

0.0

12.0

NFT -

□□□RM2

24.0

24.0

0.0

24.0

SAN3-40M

NFT -

□□□RM3

40.0

40.0

0.0

40.0

SAN3-120TM

NFT -

□□□RM4

80.0

80.0

0.0

80.0

SAN3-120WM

NFT -

□□□RM5

120.0

120.0

0.0

120.0



Data No.1A 1 Pulse Reverse Torque [Nm, Kgm...]

Setting range: 0 ~ [10: Calibration torque] × 1.1
Maximum torque value that will be applied to the fastener in reverse when the 1 Pulse reverse func-
tion is enabled.

1 Pulse reverse is used to disengage the Socket from the Fastener when a locking condition can oc-
cur.

Data No.55 1 Pulse Reverse Speed [rpm]

Setting range

: 1 ~ Tool’s maximum rpm

Speed value that will be applied to the fastener in reverse when the 1 Pulse reverse function is ena-
bled.

Data No.64 1 Pulse Reverse Time [sec]

Setting range: 0 ~ 99.9
Time value that will be applied to the fastener in reverse when the 1 Pulse reverse function is ena-
bled. The Reverse operation will be maintained for as long as this time is set for.