FEC AFC1500 Operations Manual

Chapter 4: System Setup and Wiring (Rev. 6:10/09)

Page 4-17

S

A

N

2

P

in

#

S

A

N

3

P

in

#

SIGNAL NAME

DESCRIPTION

8

8 SYNC

Input /output signal that is directly connected to other San Units to
provide for Synchronized 2nd. step fastening.
AVAILABLE IN STAND ALONE OPERATION ONLY,

9

9 WORK SELECT 3

Work / Parameter Select Input (Normally Open).
Works in combination with Work Select inputs 0 ~ 2 to provide selec-
tion of up to 16 different parameter sets.
Refer to Section 4.7.2 Work / Parameter Select Table.
AVAILABLE IN STAND ALONE OPERATION ONLY,

10 WORK SELECT 4

Work / Parameter Select Input (Normally Open).
Works in combination with Work Select inputs 0 ~ 3 to provide selec-
tion of up to 32 different parameter sets.
Available in SAN3 and SAN4 only.
Refer to Section 4.7.2 Work / Parameter Select Table.
AVAILABLE IN STAND ALONE OPERATION ONLY,

10 13 IN COMMON

Input signal common. Connection to +12 ~ 24 VDC required.

11 14

SELF CHECK
DISABLE

FASTENING END
BY SELF CHECK
OFF SIGNAL

REF. Section
4.6.10

When activated prior to the START Input signal, the performance of
the automatic Self Check (Calibration Check portion only- Zero check
is still performed) function at the beginning of the fastening cycle is
disabled.

When this function is enabled, the system will fasten to STANDARD
Torque or Angle and continue to Fasten until the High limit is
reached. If activated after reaching STANDARD but prior to the
High limit, the fastening operation will stop and a judgment is per-
formed. (Enabled in AFC Software Preferences & selected in each
Parameter)

AVAILABLE IN BOTH STAND ALONE AND WITH MULTI.

12

13

15

16

BANK SELECT 1

BANK SELECT 0

Bank Select Input Signals (Normally Open)
These two (2) inputs form a binary code that is used to define the
function / definition of outputs for Bank Data 0~7.

This allows up to 32 different output definitions with only 8 discrete
outputs (4 Banks, 8 available outputs per Bank).
See 4.7.3 Bank Select Table.

14

15

16

17

18

19

WORK SELECT 0

WORK SELECT 1

WORK SELECT 2

Work / Parameter Select Input (Normally Open)
These 3 inputs and input 9 form a binary code which is capable of se-
lecting up to 16 different sets of Fastening Parameters.

Refer to Section 4.7.2 Work / Parameter Select Table.
AVAILABLE IN STAND ALONE OPERATION ONLY,

17 23

OUTPUT
COMMON

Output signal common. Connection to 0 VDC required

OUTPUT SIGNALS