Chapter 9: Troubleshooting

Page 9-12

9.9.4 Code 8-6 servo amplifier error / iNPUT voltage abnormal

The SAN controller servo power supply circuit has detected improper input voltage either
above or below the specified limits

This abnormal is caused from;
1. The controller internal power supply has failed
2. Source voltage is out of the limit (180-242 volts AC) and/or the environment temperature is
also close to the limit.
3. One or more phases of input power is missing

RECOVERY:
1. Replace the controller
2. Provide additional cooling to the enclosure.
3. Verify and correct the source voltage as required. Between 180-242 VAC 3 phase.


9.9.5 Code 8-9

SERVO AMPLIFIER ERROR/ OVER SPEED.

The resolver signal received at the SAN controller indicates an overspeed condition.

This abnormal is caused from;
1. The resolver cable or resolver has failed.

RECOVERY:
1. Check resolver using method in 8.2.2
2. Replace resolver cable to spare cable
3. Replace tool assembly.


9.9.6 Code 8-10

SERVO AMPLIFIER ERROR / OVER LOAD ( I SQUARE T)

The duty cycle of the fastening application is too severe for this size of tool, or for the para-
meters currently setup.

RECOVERY:
1. Reduce duty cycle - Increase tool “downtime or off time” and/or increase torque speed to
reduce the amount of time running at high torque/slow speed.
2. If the problem remains, a larger tool assembly may be required for this application. Please
contact FEC.
3. Confirm that Crossover Torque is not set between 95% - 100% of Standard Torque – See
note @ 6.3.

9.9.7 Code 8-11

SERVO AMPLIFIER ERROR

/

RESOLVER SIGNAL ERROR.

The resolver signal received is not correct.

RECOVERY:
1. Check the cables and look for loose connectors or visible damages to the cable.
2. Replace with known good tool.