2 fastening preset / result displays, 3 fastening presetting / result display controls – FEC AFC1500 User Manual

Page 117

Advertising
background image

AFC1500 Operations Manual

Chapter 7: System Operations (Rev. 6.1: 1/13)

Page 7-3

7.1.2 Fastening Preset / Result displays.

w[D-NO] Data number indicator (2 digits).

Indicates the Display mode and data type (number)

・No digit: Status Display mode
・One digit: Real Time Display mode
・Two digits: Parameter Display mode

・Digit on the left : Fastening Result Display mode

w[DATA] Data value indicator (4 digits).

Displays the data specified by [D-NO] while in any display mode (refer to applicable section).

w[PARM] Parameter number/Abnormal number indicator (2 digits).

Display for the parameter number of the last fastening parameter run when in Fastening Re-
sults Display mode, or the selected parameter when in Parameter Display or Setup mode.
Also displays an abnormal code during an abnormal condition. When the CAL switch is
pressed, "E" is shown if the FULL-SCALE preset value is missing or a wrong tool is connect-
ed (Refer to Chapter 9).


Abnormal “A9” Display

Parameter No. 1

Cal “E” Fault


7.1.3 Fastening Presetting / Result Display Controls.

wMODE button

PUsed to change modes while in the Run state. (Refer to 7.2)

PUsed to move the cursor while in the Bypass (program) state. (Refer to 7.3)

wSET button

PUsed to enter Data edit mode, and to confirm data setting change.

w[

] and [

] Cursor key (vertical arrows).

PUsed to scroll through available (16) parameter numbers. (PARM)

PUsed to scroll through available data preset items. (D-NO)

PUsed to change display data values. (DATA)

Used as YES/NO acknowledge for Tool type and Torque unit changes. (Fig 7-3-6)



D-NO

PARM

D-NO

D-NO

PARM

PARM

Advertising