5 plc wiring sample – FEC AFC1500 User Manual

Page 68

Advertising
background image

Chapter 4: System Setup and Wiring

Page 4-24

4.7.5 PLC Wiring Sample

This diagram represents standard I/O connections. For synchronous fastening connection,
Please refer to section 4.7.6: Synchronized Fastening Operation.




FIG. 4-7-5 PLC Wiring Sample


All AFC1500 inputs and outputs (I/O) are active true low and must be only be connected to
devices that accommodate active true low logic for correct operation. Inputs are sourced
(normally high) and activated when pulled low (0 VDC).

Outputs are rated at +12~24 VDC, 200mA. When activated, open collector sink outputs
(normally high) pull the input device signal low. (0 VDC). To ensure correct operation of
AFC1500 output circuits, do not connect to an input device with high Input resistance.

1K Ω

2.3 KΩ

PLC side connection

SAN unit “PLC” connection

AFC1500

Outputs

Output signal

50 mA Max

0 VDC

Common

Output signal

50 mA Max

+24 VDC

Common

Input signal

(Active Low)

Input signal

(Active Low)

2.2 KΩ

0 VDC Common

+ 24 VDC

AFC1500

Inputs

24 VDC Power Supply