7.2.4 Parameter Display Mode

Parameter Display mode displays the preset values programmed in the SAN unit for fas-
tening operation. The AFC1500 system can store up to 16 different sets of parameters that
can be selected by input signals WORK SELECT 0 ~ 3 (see section 4.7.2.) In addition to pa-
rameter 1 ~ 16 there is a PARAMETER 0 that contains configuration data common to all pa-
rameters.

Note: Representation only, not actual data


The data displayed in this section is the DISPLAY only for the Configured Parameters.
To enable programming changes of these values the system must be switched to
Download/Set-up Mode (Section 7.3)

FIG. 7-2-4a Parameter number selection

Parameter No.16

Parameter No.15

Parameter No.14

Parameter No.03

Parameter No.02

Parameter No.01

00: Fastening Mode
10: Calibration torque
11: Peak Low Torque
12: Peak High Torque
13: Standard Torque


71: High Current Limit
72: Low Current Limit
73: Controlled Current

Parameter No.00
System Parameter

00: Torque Unit
01: NR Version
02: Amplifier Version
03: Function Version
04: External Gear Ratio



20: Tool No.