Chapter 7: System Operations

Page 7-12



Data No.00 Fastening Mode (Method + Steps)


□ □ □ □
[Fastening Method]

0: Torque method 2: Current (Torque) Method
1: Angle method 3: Current (Angle w/ Continuous Snug torque)

[Fastening Steps]
0: 1Step Fastening SNUG TQ Angle origin (for Backouts) (*1)
1: 1 Step Fastening
2: 2 Step Fastening - Pre-stop at 1

ST

Torque/Angle

3: 3 Step Fastening - Pre stops at 1

ST

and CROS Torque/Angle



[Fastening Direction]
0: CW Direction Fastening
1: CCW Direction Fastening
(For special fastenings such as left-hand screws. Reverse direction is CW.)

[Reverse Operation]
0: Reverse operation will reach the set speed from the start.
1: Reverse operation will start rotation at the speed of 20rpm for 1.5
second, then reach the set speed.

(*1) The difference between SNUG TQ Angle Origin Fastening Method and other fastening methods

The angle measurement method from SNUG TORQUE differs.
There is no difference for normal fastening applications. Therefore, select fastening mode
# XX10, XX11, XX20, XX21.


◎ 1 Step Fastening Angle Method (XX11)
Angle value is not counted up when torque is below SNUG TORQUE.

[In case Standard Angle is 90 °]

50°

40 °

SNUGTQ



◎ 1 Step Fastening SNUG TQ Angle Origin Angle Method (XX01)
Once SNUG TORQUE is reached, angle value is counted up regardless of the torque value.

[In case Standard Angle is 90 °]

90 °

SNUG TQ

[Fastening][Torque][Angle][Rate][Time][Rotation Speed][Revolutions][Current] Parameter

Parameter No.01 ~16