FEC DSP1500 (SAN3) User Manual

Page 100

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev 4)

PAGE 6-24

Chapter 6: System Operation

Item

Parameter No.

PARM

Data No.

D-NO

DATA

Speed

01~32

70

Slow Start Speed [mm/sec]

01~32

71

Approach Speed [mm/sec]

01~32

72

Part Search Speed [mm/sec]

01~32

73

Press Speed 1 [mm/sec]

01~32

74

Press Speed 2 [mm/sec]

01~32

75

Decompression Speed [mm/sec]

01~32

76

Return Speed [mm/sec]

¾

Data Number

00

Press ModePress MethodJudgment OperationLoading

DirectionReturn Operation

This data field will set the Press Method, Judgment Operation, Loading Direction and
Return Operation.


□ □ □ □

Press Method

0:

Load Control

1:

Distance Control

2:

Specified Point Load Judgment

3:

Load

Rise

Detection

4:

Specified Range Peak Load Judgment

5:

Time Controlled Press

6:

Load Drop Detection

7:

Load Drop Detection (Point Stop)

8:

Distance Control with Load Limit


Judgment Operation

0:

Final Load Low Limit Judgment Disable

1:

Final Load Low Limit Judgment Enable

2:

Final Load Low Limit Judgment Disable + Part 3 Check

3:

Final Load Low Limit Judgment Enable + Part 3 Check

* 4:

Final Load Low Limit Judgment Disable + Band Check

* 5:

Final Load Low Limit Judgment Enable + Band Check

(*Must

be

enabled

in

System

Setting

[00-38]

to

use)

Loading

Direction

0:

Positive Load (Default)

1:

Negative Load

Return Operation

0:

Return

1:

[ACCEPT] Return, [REJECT] No Return

2:

[ACCEPT] No Return, [REJECT] Return

3:

[ACCEPT] and [REJECT] No Return

4:

Jog Return

5:

Keep Load

6:

Load Ignore Return

7:

Load Return (Software version 1.94 or later)



*For further detailed Press Mode instruction, see the following items.