Part Check 3 settings are available when the Judgment Operation is set to 1 or 3. Set these
values if additional Check Limits are required during the load portion of the press operation.

¾

Data Number 23 - Part Check 2 Load Low Limit

¾

Data Number 24 - Part Check 2 Load High Limit

ƒ

The minimum and maximum acceptable limits for the measured load value occurring

between [44: Part Check 2 Start Distance] and [45: Part Check 2 End Distance].
A Low Limit setting is possible from 0 to full-scale value.
A High Limit setting is possible from 0 to 110% of full-scale value.

¾

Data Number 44 - Part Check 2 Start Distance

ƒ

The distance at which “Part Check 2” starts. This distance is measured from

the [18: Distance Measurement Start Load] value.
A setting is possible from 0 to stroke distance limit.

¾

Data Number 45 - Part Check 2 End Distance

ƒ

The distance at which “Part Check 2” ends. This distance is measured from

the [18: Distance Measurement Start Load] value.
A setting is possible from 0 to stroke distance limit.

¾

Data Number 25 - Part Check 3 Load Low Limit

¾

Data Number 26 - Part Check 3 Load High Limit

ƒ

The minimum and maximum acceptable limits for the measured load value occurring

between [46: Part Check 3 Start Distance] and [47: Part Check 3 End Distance].
A Low Limit setting is possible from 0 to full-scale value.
A High Limit setting is possible from 0 to 110% of full-scale value.

¾

Data Number 46 - Part Check 3 Start Distance

ƒ

The distance at which “Part Check 3” starts. This distance is measured from

the [18: Distance Measurement Start Load] value.
A setting is possible from 0 to stroke distance limit.

¾

Data Number 47 - Part Check 3 End Distance

ƒ

The distance at which “Part Check 3” ends. This distance is measured from

the [18: Distance Measurement Start Load] value.
A setting is possible from 0 to stroke distance limit.



















Load

[44]

Part Check 2

Start Distance

Final Position

Time/
Distance

[45]

Part Check 2

End Distance

[46]

Part Check 3
Start Distance

[25] Part Check 3

Load Low Limit

[24] Part Check 2

Load High Limit

[23] Part Check 2

Load Low Limit

[26] Part Check 3

Load High Limit

[47]
Part Check 3

End Distance

[18] Distance

Measurement

Start Load

Part Check 3

Advertising