DSP1500 SAN Unit Operation Manual

PAGE 8-7

(Rev.

4)

Chapter 8: Troubleshooting

Code A3_4 - CCW SENSOR POSITION ABNORMAL

The resolver count is out of the 1000 ~ 3000 range after performing a Home Position Search.
(See Section 7.2.3.2 for an explanation of Home Position Search)
Note: The press unit will still be able to operate with this abnormal but be warned that, if
using Distance Control press methods, the distance value may fluctuate.

CAUSE:
1. The motor was changed and not “tuned” or tuned incorrectly.
2. The RETURNED switch (CCW) has moved.
3. An offset value was entered in the “Resolver Position” System Parameter [00-09] that caused

the resolver count to become out of range.

4. If using a DPS or DPM series tool, the belt tension may need adjustment.

RECOVERY:
1. Perform a “tuning” procedure on the motor. (See Section 7.2.3.3)
2. Verify that the RETURNED switch (CCW) mounting screws are tight. If loose, tighten and

perform a “tuning” procedure on the motor.

3. Enter a value of zero into the “Resolver Position” System Parameter [00-09] and download to

the controller. Perform a Home Position Search and verify that the resolver count is between
1000 ~ 3000. If it is slightly out of range, an offset value may be entered in the “Resolver
Position” System Parameter [00-09]. (See Section 6.4.5.1 for an explanation of the “Resolver
Position” System Parameter [00-09])

4. Verify that the motor fixing bolts on the DPS or DPM tool are tight and the belt is at the

correct tension. (See Section 7.1.1.3)


Code A3_5 - ORIGIN SEARCH TIMEOUT

The Home Position Search operation did not finish in the time specified in System Parameter
00-30. (See Section 7.2.3.2 for an explanation of Home Position Search)

RECOVERY:
1. Increase the Home Position Search Time Out specified in System Parameter 00-30.

(See Page 6-21)

2. Increase the Home Position Search Speed specified in System Parameter 00-31.
3. Verify that the Home Position Sensor setting specified in System Parameter 00-36 is set

correctly.