DSP1500 SAN Unit Operation Manual

PAGE 6-27 (Rev

4)

Chapter 6: System Operation

Specified Point Load Judgment (Method 2)


This Load Control press method allows judgment of a load (PS) at a given distance
[34: Judgment Load Detection Point].
Upon start of cycle, the press will operate until it achieves [14: Target Load]. During
the press cycle, checks are performed for “Interference Check” / “Part Check”, Load
and Distance. If any of these values are compromised, the press will stop and return as
programmed.

The Final Judgment will be based upon the load value (PS) at

[34: Judgment Load Detection Point]

.

(See corresponding sections for Interference Check and Part Check explanations.)





















Load

Distance

[11] Final Load High Limit

[12] Load Low Limit

[14] Target Load

[31]

Distance

Low Limit

[32]

Distance

High Limit

Final Judgment Zone

[34]

Judgment Load
Detection Point

Judgment Load (PS)

[13] Load High Limit