FEC DSP1500 (SAN3) User Manual

Page 82

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev 4)

PAGE 6-6

Chapter 6: System Operation

6.2 Function of Display and Operating Panel



[START]: Cycle START Button
Pressing this button initiates the press cycle. The press will
perform the operation as defined in the active parameter
while pressing.
This button must be held until the press cycle ends. If the
button is released in the middle of the operation, the press
will stop and, if programmed to do so, will return.

[MANUAL]: MANUAL Mode (Jog) Button
While pressing this button and the [↑] button at the same
time, the press will jog in the return direction.
While pressing this button and the [↓] button at the same
time, the press will jog in the advance direction.
Pressing this button and the [START] button at the same
time will enable Home-Position Search operation.
Pressing this button and the [SET] / (HOME) button at the
same time will enable Home-Position Return operation.

The speed of MANUAL movement is set in Data Parameter 0e. Manual speed can be increased
or decreased by changing this value.

[CAL]: CAL Voltage Check Button
Press this button to obtain the CAL voltage level from the press load cell pre-amplifier. This
value is compared to the data stored in memory. If the difference is within the allowed range, the
ACCEPT LED will light. If the difference is not within the allowed ranged, the REJECT LED will
light and an abnormal will be generated. The system will be disabled until the abnormal is reset.

[RESET]: RESET Button
Press this button to reset the SAN Unit.
If this button is pressed during a press cycle, the unit will stop and all press data and output
signals will be reset. Also, the Zero Level of the load cell will be checked. If it is within the
acceptable range, the ACCEPT LED will light. If is not within the acceptable range, the REJECT
LED will light and an abnormal will be generated. The system will be disabled until the abnormal
is reset.


DATAData Display (4 digits)

The operation result and each setting data are displayed.

PARMParameter Number / Abnormal Code Display (2 digits)

The parameter number used for operation is displayed after the operation finishes.
When an abnormal occurs, the abnormal error code will be displayed.

D-NOData Number / Abnormal Sub-Code Number Display (2 digits)

Displays the Data Numbers for the selected parameter when programming.
Displays the Data Code Number when in Real Time Display Mode or Operating Result
Display Mode.
Press Unit number (U.01 to U. 32) is displayed right after powering on or after reset.

[MODE]: Mode Button

Used to change modes and while in the RUN state.
Used to move the cursor while in the BYPASS (program) state.

[SET] / (HOME): Set Button

Used to enter the data in edit mode, and to confirm data setting changes.

[↑],[↓]: Cursor Buttons

Used to scroll the displayed data and change data setting.

Manual Operation Buttons

Data Display - 7 Segment LED

Data Display Operation Buttons

Advertising