FEC DSP1500 (SAN3) User Manual

Page 98

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev 4)

PAGE 6-22

Chapter 6: System Operation

¾

Data number

37

Distance High Limit Stop / Distance Sampling / Deadman Function


□ □ □ □

0: Distance High Limit Stop [Yes] (Default)

1: Distance High Limit Stop [No]

* When set to “1”, Stroke Distance Limit [00-33] is used for judgment.

0: 0.1mm distance sampling (Default)

1: 0.01mm distance sampling

2: 0.005mm distance sampling

* For correct waveform sampling, the speed should be at or less than
20mm/sec. for 0.1mm, 2mm/sec. for 0.01mm and 1mm/sec. for 0.005mm.


Deadman Function:

0: Normal (Default)

1: Home Position Search Only

2: Return Only

3: Home Position Search and Return

RS232 Output Select:

0: No Data Output (Default)

1: Press Result Data Output

2: Waveform Display

¾

Data number

38

Band Check *


□ □ □ □

0: Disable [No] (Default)

1: Enable [Yes]

*(Requires Main Unit firmware version 1.06 and/or SAN Unit firmware version 3.11

minimum)

¾

Data number

39

(Reserved for special functions. Do Not Use.)

* Data number 40, 41, 42 and 43 require the use of a SAN3-DP(1 or 2)S module (new

version) and SAN Unit firmware version 3.18 minimum.

¾

Data number

40

Real Time Clock - Date: Year Data


□ □ □ □

¾

Data number

41

Real Time Clock - Date: Month / Day Data


□ □ □ □

¾

Data number

42

Real Time Clock - Time: Hours / Minutes Data (24 Hour Clock)


□ □ □ □

¾

Data number

43

Real Time Clock - Time: Seconds Data


□ □ □ □

8

0

0

2 =

“2008”

9

0

7

= “07 / 09” (July 9

th

)

0

1

5

1 =

“15:10”

(3:10PM)

0

5 =

“:50”