These settings are used to turn the Advance/Return (Timing) Position Signal Output on and off.
These settings and output signals may be useful when interfacing with other fixture processes or
tooling (IE: vacuum, clamps, etc.) or when other processes need to know when the press ram is
clear.

¾

Data Number 50 - Advance Position ON Distance

¾

Data Number 51 - Advance Position OFF Distance

ƒ

When set to a number other than zero, these settings control the “On” and “Off” of the

Advance/Return Position Signal output while the press is advancing.
*When the press is set up for Negative Load direction, Advance Position is output while
the press is returning (moving toward target).

¾

Data Number 52 - Return Position ON Distance

¾

Data Number 53 - Return Position OFF Distance

ƒ

When set to a number other than zero, these settings control the “On” and “Off” of the

Advance/Return Position Signal output while the press is returning.
*When the press is set up for Negative Load direction, Return Position is output while the
press is advancing (returning from target).


































50

53

ON

OFF

51

OFF

ON

52

0mm

150mm

Example #1

[50: 50.0mm]
[51: 120.0mm]
[52: 150.0mm]
[53: 100.0mm]

50

53

ON

OFF

150mm

Example #2

[50: 50.0mm]
[51: Max Distance]
[52: Max Distance]
[53: 100.0mm]

0mm

Advance / Return Position Signal Output