DSP1500 SAN Unit Operation Manual

PAGE 4-11 (Rev.

4)

Chapter 4: System Setup and Wiring

4.7.2 PLC Interface (I/O) Signals [Stand Alone Configuration]

IN: Input Signal OUT: Output Signal NC: Normally Closed NO: Normally Open




4.7.2.1 Output Data Bank Signals (Stand Alone Configuration Only)

Bank Select Inputs are used to “multiplex” the output signals allowing up to 32 signals from only 8
physical outputs. By changing the input conditions of these two inputs, up to four “Banks” may be
selected changing the definition of each output point.


The SERVO ON signal is sometimes monitored to operate the brake. When changing
Banks, the meaning of the SERVO ON signal will change when a bank other than Bank
1 is selected. (See Section 4.14 for Brake Operation)





Pin No.

Signal Name

IN/OUT

Description

1

STOP

IN (N.C.) Stops System operation upon loss of signal.

2

RESET

IN (N.O.) Resets to the initial condition. (>100 ms pulse)

3 MANUAL

IN

(N.O.)

Manual

mode.

4

START

IN (N.O.) Starts Press Cycle.

5

BYPASS

IN (N.O.) Disables Press operation.

6 NOT

USED

No

Connection

Allowed

7 NOT

USED

No

Connection

Allowed

8 NOT

USED

No

Connection

Allowed

9

HOME / OPTION IN

IN (N.O.) Home sensor input/Option In input (Use for special applications)

10

BANK 1

IN (N.O.) Bank 1 Select input

11

BANK 0

IN (N.O.) Bank 0 Select input

12 NOT

USED

No

Connection

Allowed

13

IN COMMON

Input signal common. (+12 ~ +24VDC)

14

SELF CHECK OFF

IN (N.O.) Disable the self-check function.

15

CW LIMIT

IN (N.C.) CW limit sensor input.(Advance limit)

16

CCW LIMIT

IN (N.C.) CCW limit sensor input.(Return limit)

17

WORK SELECT 0

IN (N.O.) These 5 inputs form a binary code which is capable of selecting up to

32 different parameters.
(In Manual Mode these inputs become selecting signals for advance,
return, home-position search and home-position return operations.)

18 WORK

SELECT

1

IN

(N.O.)

19 WORK

SELECT

2

IN

(N.O.)

20 WORK

SELECT

3

IN

(N.O.)

21 WORK

SELECT

4

IN

(N.O.)

22 OUT

DATA11

OUT (N.O.) Echo of Bank 0 Select Signal

23

OUT COMMON

Output signal common. (0VDV)

24 OUT

DATA0

OUT (N.O.)





Outputs system condition signals based on which Bank is selected.





Echo of Bank 1 Select Signal

25 OUT

DATA1

OUT (N.O.)

26 OUT

DATA2

OUT (N.O.)

27 OUT

DATA3

OUT (N.O.)

28 OUT

DATA4

OUT (N.O.)

29 OUT

DATA5

OUT (N.O.)

30 OUT

DATA6

OUT (N.O.)

31 OUT

DATA7

OUT (N.O.)

32 OUT

DATA8

OUT (N.O.)

33 OUT

DATA9

OUT (N.O.)

34 OUT

DATA10

OUT (N.O.)