Chapter 6: System Operation

Specified Range Peak Load Judgment (Method 4)


This Load Control press method allows judgment of a peak load (PS) and judgment of
the final distance (DS).
Upon start of cycle, the press will operate until it achieves [14: Target Load]. During
the press cycle, as soon as [39: Detection Start Distance] is reached, the press will
begin looking for a peak in press force (PS). The press will attempt to detect (PS) until
[40: Detection End Distance] has been reached. During the press cycle, checks are
performed for “Interference Check” / “Part Check”, Load and Distance. If any of these
values are compromised, the press will stop and return as programmed.

Judgment is

based on the press force peak (PS) while within the “Detection Range”. Final Judgment
is based on the distance (DS) where the press force reaches [13: Target Load].

(See corresponding sections for Interference Check and Part Check explanations.)


















Load

Distance

[11] Final Load High Limit

[12] Load Low Limit

[14] Target Load

[31]

Distance

Low Limit

[32]
Distance

High Limit

Final Judgment Zone

[40]

Detection

End Distance

Judgment Load (PS)

[13] Load High Limit

(DS)

Judgment Distance

Detection

Range

Judgment Zone

[39]

Detection

Start Distance