FEC DSP1500 (SAN3) User Manual

Page 142

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev. 4)

PAGE 8-8

Chapter 8: Troubleshooting

8.5 System Memory Errors [ A4_* ]

Code A4_0 - SYSTEM MEMORY ERROR / FLASH ROM WRITE ERROR

Communications error to internal SAN Flash ROM during WRITE attempt.

CAUSE:
1. Metal chips and/or debris have migrated inside SAN Unit through vent holes.
2. Flash ROM IC chip has malfunctioned.

RECOVERY:
1. Remove SAN Unit and blow or shake out debris.
2. Replace and return unit to FEC for repair.

Code A4_1 - SYSTEM MEMORY ERROR / FLASH ROM READ ERROR

Communications error to internal SAN Flash ROM during READ attempt.

CAUSE:
1. Metal chips and/or debris have migrated inside SAN Unit through vent holes.
2. Flash ROM IC chip has malfunctioned.

RECOVERY:
1. Remove SAN Unit and blow or shake out debris.
2. Replace and return unit to FEC for repair.

Code A4_2 - SYSTEM MEMORY ERROR / SERVO AMP FLASH ROM ERROR

Communications error to internal SAN Servo Amp flash ROM.

CAUSE:
1. Metal chips and/or debris have migrated inside SAN Unit through vent holes.
2. Flash ROM IC chip has malfunctioned.

RECOVERY:
1. Remove SAN Unit and blow or shake out debris.
2. Replace and return unit to FEC for repair.
























Advertising