FEC DSP1500 (SAN3) User Manual

Page 59

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

PAGE 4-19 (Rev.

4)

Chapter 4: System Setup and Wiring

ƒ

WORK SELECT 4: [OUT DATA3] Work Select 4 Input Echo Signal

Output when the WORK SELECT 4 input is high (On).

ƒ

WORK SELECT 3: [OUT DATA4] Work Select 3 Input Echo Signal

Output when the WORK SELECT 3 input is high (On).

ƒ

WORK SELECT 2: [OUT DATA5] Work Select 2 Input Echo Signal

Output when the WORK SELECT 2 input is high (On).

ƒ

WORK SELECT 1: [OUT DATA6] Work Select 1 Input Echo Signal

Output when the WORK SELECT 1 input is high (On).

ƒ

WORK SELECT 0: [OUTDATA7] Work Select 0 Input Echo Signal

Output when the WORK SELECT 0 input is high (On).

ƒ

BANK 1: [OUT DATA10] Bank 1 Input Echo Signal

Output when the BANK SELECT 1 input is high (On).

ƒ

BANK 0: [OUT DATA11] Bank 0 Input Echo Signal

Output when the BANK SELECT 0 input is high (On).

ƒ

LOAD_LOW: [OUT DATA0] Low Load REJECT Signal

Output when the press result is below the acceptable Low Load Limit.

Output remains active until the start or reset signal is input.

ƒ

LOAD_HIGH: [OUT DATA1] High Load REJECT Signal

Output when the press result has exceeded the acceptable High Load Limit.

Output remains active until the start or reset signal is input.

ƒ

DIS_LOW: [OUT DATA2] Low Distance REJECT Signal

Output when the press result is below the acceptable Distance Low Limit.
Output remains active until the start or reset signal is input.

ƒ

DIS_HIGH: [OUT DATA3] High Distance REJECT Signal

Output when the press result exceeds the acceptable Distance High Limit.
Output remains active until the start or reset signal is input.

ƒ

CK1_LOW: [OUT DATA4] Part Check 1 Low / Interference Zone REJECT Signal

Output when the distance where Part Check 1 Load is sensed is below the
acceptable Part Check 1 Distance Low Limit.
Output along with CK1_HIGH signal when an Interference Zone Reject occurs.
Output remains active until the start or reset signal is input.

ƒ

CK1_HIGH: [OUT DATA5] Part Check 1 High / Interference Zone REJECT Signal

Output when the distance where Part Check 1 Load is sensed is above the
acceptable Part Check 1 Distance High Limit.
Output along with CK1_LOW signal when an Interference Zone Reject occurs.
Output remains active until the start or reset signal is input.

ƒ

CK2_LOW: [OUT DATA6] Part Check 2 Low REJECT Signal

Output when the load sensed by the press between Part Check 2 Start Distance and
Part Check 2 End Distance is below the acceptable Part Check 2 Load Low Limit.
Output remains active until the start or reset signal is input.


OUTPUT BANK 2: Bank0 – On / Bank1 - Off

OUTPUT BANK 3: Bank0 – Off / Bank1 - On