FEC DSP1500 (SAN3) User Manual

Page 64

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev. 4)

PAGE 4-24

Chapter 4: System Setup and Wiring

4.9 MON. Signal (External Monitor Signal)

This auxiliary connector is used to output Load, Position, Current and Speed signals to external
equipment for monitoring purposes. This connection is not required for the system to operate.

enFORCE

outputs 1 digital pulse per 0.1mm moved distance and press proportionate to load by

the MON>OUT connectors. (There are some time differences in the distance pulse)


Mating Connector

Manufacture: Molex
Housing Part No.: 39-01-2065
Contact Part No.:

30-00-0047 (Qty.-6)


NO Signal Name IN/OUT Description
1 LOAD OUT

OUT Load voltage Monitor Output full-scale load Δ 2.5V

2

POSITION PULSE OUT Distance pulse Monitor Output 5V TTL Signal

3 POSITION

CW/CCW

OUT Advance/Return Monitor Output 5V TTL Signal

4 Current Monitor OUT -10V~+10V (+10V=SAN24S:24A/ SAN40S:40A/ SAN120S:120A)
5 Speed Monitor

OUT -10V~+10V (+10V = Maximum Speed)

6

GND

GND for Monitor Signal Output


LOAD OUT

- Load Voltage (Analog Voltage)

Monitor voltage represents zero load to full-scale load by an electric potential difference of
2.5V.

Home-position voltage is voltage measured when the press is stopped.

The Home position voltage is not 0V. (It may differ but the voltage is within
-2V to +2V)
Home position voltage of the same tool type differs as well.

Example: If the Home position voltage is –0.5V, the full-scale load voltage

is +2.0V and the voltage change (potential difference) is 2.5V.

*This signal will not output without a load transducer.


POSITION PULSE

- Distance Pulse:

(TTL

signal 0V or 5V)

Distance pulse is output at 1 pulse per 0.1mm. It slightly differs from the actual distance
moved.

POSITION CW/CCW

- Advance/Return Signal: (TTLsignal 0V or 5V)

HIGH signal is output on advance (clockwise revolution) and LOW signal is output on return

(counter-clockwise

revolution).

0.1mm


Distance Pulse

Advance/Return Signal


Advance Stop


Operating Condition Return

*This is based on the rotation direction of the motor so it may show “Advance” while returning

and vise-versa for tools with inverted motors or different gearing.