DSP1500 SAN Unit Operation Manual

(Rev 4)

PAGE 7-10

Chapter 7: Maintenance & Inspection




Mark X & Y position for Ref.











Mark X & Y position for Ref.





Press Part Number

If reading is

(0~1000), move

If reading is

(3000~4095), move

Move for every 1000

pulses (approx)

DPT-021R1-**F Down

Up

0.75mm

DPT-021R3-**P Down

Up

0.31mm

DPT-051R2A-**F Up

Down

0.42mm

DPT-051R3-**P Up

Down

0.14mm

DPT-101R3-**F Up

Down

0.42mm

DPT-101R4H-**P Up

Down

0.42mm

DPS-101R3-**F Down

Up

0.33mm

DPT-151R3-**F Up

Down

0.42mm

DPT-151R4H-**P Up

Down

0.36mm

DPT-201R3-**F Up

Down

0.25mm

DPT-201R4H-**P Up

Down

0.25mm

DPT-301R4H-**F Down

Up

1.00mm

DPT-301R4H-**P Up

Down

0.20mm

DPS-301R4H-**F Down

Up

0.63mm

DPT-501R4H-**F Down

Up

0.63mm

DPT-501R5B-**P Up

Down

0.25mm

DPS-501R4H-**F Down

Up

0.50mm

DPT-701R4H-**F Down

Up

0.42mm

DPT-701R5-**P Up

Down 0.18mm

Presses larger than 10 ton cannot be adjusted this way because of the use of the Origin switch.
“Up” is a movement towards the gear housing and “Down” is a movement towards the press ram.