Chapter 6: System Operation

6.3.4 Real Time Display Mode

The following data is displayed on the screen in the Real Time Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.

D-NO DATA

0

Load value display

Displays present load applied on the load cell in real time.

1

Load voltage value display

Displays present load signal voltage applied on the load cell in real time.

2

Maximum load value display (Maximum value hold)

Displays peak load from the time when the [RESET] switch was last pressed in this mode.

3

Moving distance display

Displays distance of absolute position from the home position.
Press and hold [SET] to see the 3 decimal place resolution value.

4

Electronic thermal value (Overload at 100)

Present electronic thermal value is displayed.

5

Current value (Max 1023)

Displays present current value.

6

Resolver position data display (0 to 4093)

Displays present resolver position.

7

Input and Output signal monitor (Software version 1.96 or later)

Displays ON/OFF state of PLC I/F input and output signal. (See below for details.)

8

For in-house use only














Input and output signal monitor

* This can be used for firmware version 1.96 or later of the SAN unit.











D-NO

: 1 Digit Display

0

1

2

[

↑], [↓]

switch

“D-NO” “DATA”

Load value display

Load voltage value
display

Maximum load value
display

n

ON: Lights up OFF: Lights off