FEC DSP1500 (SAN3) User Manual

Page 112

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev 4)

PAGE 6-36

Chapter 6: System Operation


¾

Data Number 30 - Final Distance High Limit (Methods 3, 6 and 7)

ƒ

In special press methods which may be judging two different zones, this is the final target

distance high limit.

A setting is possible from 0 to stroke distance limit.

¾

Data Number 31 - Distance Low Limit

¾

Data Number 32 - Distance High Limit

ƒ

Minimum and maximum acceptable distance limits for the target distance or load.

In Load Control, if [32: Distance High Limit] is reached before achieving [14: Target
Load]
, the press will stop.
A setting is possible from 0 to stroke distance limit.

¾

Data Number 33 - Target Distance

ƒ

In Distance Control Methods, this is the target distance value.

(Example: If Target Distance is 100mm, press will attempt to operate until 100mm is
reached.)

A setting is possible from 0 to stroke distance limit.

¾

Data Number 34 - Judgment Load Detection Point (Method 2)

ƒ

In the [Specified Point Load Judgment] method, this is the distance at which the load will

be judged. Judgment is carried out at the end of the cycle.

A setting is possible from 0 to stroke distance limit.

¾

Data Number 35 - Approach Distance

ƒ

The distance of Approach Speed operation. This distance is measured from [41: Job

Start Position], not from end of [60: Slow Start Time].

A setting is possible from 0 to approach distance limit.

¾

Data Number 37 - Press Speed 1 Start Distance

ƒ

The distance at which Part Search Speed will change to Press Speed 1.

A setting is possible from 0 to stroke distance limit.

¾

Data Number 38 - Press Speed 2 Start Distance

ƒ

The distance at which Press Speed 1 will change to Press Speed 2.

A setting is possible from 0 to stroke distance limit.

¾

Data Number 39 - Detection Start Distance (Methods 3, 4, 6 and 7)

ƒ

In certain special press methods, this is the distance at which the press will begin looking

for the programmed judgment value.

A setting is possible from 0 to stroke distance limit.

¾

Data Number 40 - Detection End Distance (Method 4)

ƒ

In [Specified Range Peak Load Judgment] method, this is the distance at which the press

will stop looking for the programmed judgment value.

A setting is possible from 0 to stroke distance limit.

¾

Data Number 41 - Job Start Position

ƒ

The press will go back to this position after operating when a Return Operation is set.

A setting is possible from 0 to stroke distance limit.

If a Return Operation is set and the Start signal goes low (OFF), the press will
move to this position.







Í