DSP1500 SAN Unit Operation Manual

(Rev 4)

PAGE 6-42

Chapter 6: System Operation



(Requires Main firmware version 1.06 and/or San Unit firmware version 3.11 minimum)
*Setup should be performed using the DSP User Console Software. Only use the
Programming Display Panel if changes are required and a User Console PC is not
available.

This special function allows the user to define a high and low limit “band” around a known good
part curve signature and use for part judgment. Once defined, a part will be determined “good”
only if its curve signature falls within the set band limits.

Band Check is enabled in the System Settings. Once enabled, options 4 and 5 can be entered in
the Judgment Operation parameter. After the appropriate Judgment Operation has been set, data
numbers 80 through B9 become available for setting up the High and Low Limit Band set points.

¾

Data Number 80 - L1 Set Point Load Setting

ƒ

L1 (Low Limit Band - Setting 1) Load Limit Setting

¾

Data Number 81 - L1 Set Point Distance Setting

ƒ

L1 (Low Limit Band - Setting 1) Distance Limit Setting

¾

Data Number 82 - L2 Set Point Load Setting

ƒ

L2 (Low Limit Band - Setting 2) Load Limit Setting

¾

Data Number 83 - L2 Set Point Distance Setting

ƒ

L2 (Low Limit Band - Setting 2) Distance Limit Setting

¾

Data Number 84 - L3 Set Point Load Setting

ƒ

L3 (Low Limit Band - Setting 3) Load Limit Setting

¾

Data Number 85 - L3 Set Point Distance Setting

ƒ

L3 (Low Limit Band - Setting 3) Distance Limit Setting

¾

Data Number 86 - L4 Set Point Load Setting

ƒ

L4 (Low Limit Band - Setting 4) Load Limit Setting

¾

Data Number 87 - L4 Set Point Distance Setting

ƒ

L4 (Low Limit Band - Setting 4) Distance Limit Setting

¾

Data Number 88 - L5 Set Point Load Setting

ƒ

L5 (Low Limit Band - Setting 5) Load Limit Setting

¾

Data Number 89 - L5 Set Point Distance Setting

ƒ

L5 (Low Limit Band - Setting 5) Distance Limit Setting

¾

Data Number 90 - L6 Set Point Load Setting

ƒ

L6 (Low Limit Band - Setting 6) Load Limit Setting

¾

Data Number 91 - L6 Set Point Distance Setting

ƒ

L6 (Low Limit Band - Setting 6) Distance Limit Setting

¾

Data Number 92 - L7 Set Point Load Setting

ƒ

L7 (Low Limit Band - Setting 7) Load Limit Setting

¾

Data Number 93 - L7 Set Point Distance Setting

ƒ

L7 (Low Limit Band - Setting 7) Distance Limit Setting

¾

Data Number 94 - L8 Set Point Load Setting

ƒ

L8 (Low Limit Band - Setting 8) Load Limit Setting

¾

Data Number 95 - L8 Set Point Distance Setting

ƒ

L8 (Low Limit Band - Setting 8) Distance Limit Setting

¾

Data Number 96 - L9 Set Point Load Setting

ƒ

L9 (Low Limit Band - Setting 9) Load Limit Setting

¾

Data Number 97 - L9 Set Point Distance Setting

ƒ

L9 (Low Limit Band - Setting 9) Distance Limit Setting

Band Check