DSP1500 SAN Unit Operation Manual

PAGE 6-47 (Rev

4)

Chapter 6: System Operation

6.6 Return Parameter Setup

It is recommended that, if the return of the press is done with a parameter, use Distance Control.
However, if Target Distance is set to 0 without a return operation, the press will reject because the
Distance Low value is zero (a value less than zero is not possible).
Refer to the following for setting up a Return Parameter. Adjustments can be made according to
the individual application.

D-NO DATA

SETTING

00 Press

Operation

0001

(Distance Control+Return Operation)

12

Load Low Limit

13

Load High Limit

Maximum Load of the Tool

15

Interference Check Load

Maximum Load of the Tool

16

Press Speed 1 Start Load

1 or Maximum Load of the Tool

17

Press Speed 2 Start Load

Same as Press Speed 1 Start Load

18

Distance Measurement Start Load 0

22

Part Check 1 Load

. 1

31 Distance

Low

Limit

32 Distance

High

Limit

33 Target

Distance

(setting to 0 will cause a reject)

35 Approach

Distance

10

(may need to set larger for higher speeds)

36 Interference

Check

Distance

(unless required)

37

Press Speed 1 Start Distance

38

Press Speed 2 Start Distance

41 Job

Start

Position

42

Part Check 1 Distance Low Limit

43

Part Check 1 Distance High Limit

Maximum Stroke of the Tool

50 Advance

Position

ON

Distance 0

51

Advance Position OFF Distance

52 Return

Position

ON

Distance

53

Return Position OFF Distance

60 Slow

Start

Time

. 1

61

Load Hold Time

70 Slow

Start

Speed

71 Approach

Speed

100

72

Part Search Speed

10

73 Press

Speed

1

74 Press

Speed

2

75 Decompression

Speed

76 Return

Speed