enFORCE

DSP1500 SAN Unit Operation Manual

(Rev. 4)

PAGE 4-18

Chapter 4: System Setup and Wiring

ƒ

PRESS ADVANCED: [OUT DATA8 - PIN #32]

Outputs when the press reaches the target load or target distance for a time that is
set in [61: Load Hold Time].

If Load Hold Time is set to zero the PRESS ADVANCED signal will not turn
on.

ƒ

TIMING SIGNAL: [OUT DATA9 - PIN #33] (Advance / Return Position Signal Output)

Data Numbers 50, 51, 52 and 53 of Parameters 1~32 are used to set ON and OFF
limits for the Timing Signal.

[50: Advance Position ON Distance]

[51: Advance Position OFF Distance]

[52: Return Position ON Distance]

[53: Return Position OFF Distance]

This may be useful when interfacing with other fixture processes or tooling (IE:
vacuum, clamps, etc.) or when other processes need to know when the press ram is
clear.
















ƒ

BANK 1: [OUT DATA10 - PIN #34] Bank 1 Input Echo Signal

Output when the BANK SELECT 1 input is high (On).

ƒ

BANK 0: [OUT DATA11 - PIN #22] Bank 0 Input Echo Signal

Output when the BANK SELECT 0 input is high (On).









Í

50

53

ON

OFF

51

OFF

ON

52

0mm

150mm

Example #1

[50: 50.0mm]
[51: 120.0mm]
[52: 150.0mm]
[53: 100.0mm]

50

53

ON

OFF

150mm

Example #2

[50: 50.0mm]
[51: Max Distance]
[52: Max Distance]
[53: 100.0mm]

0mm