Chapter 2: Specifications

2.1 System Specifications

Power Supply Voltage

180VAC ~ 242VAC, 3 phase, 50/60Hz

Operating Conditions

Temperature

32 ~ 122°F (-0 ~ 50°C)

Humidity

20 ~ 90% (no condensation)

Storage Conditions

Temperature

32 ~ 122°F (-0 ~ 50°C)

Humidity Below

90%

(no

condensation)

Shipping Conditions

Temperature

32 ~ 122°F (-0 ~ 50°C)

Humidity Below

90%

(no

condensation)

Operating Range

Duty Cycle less than 60%

Load stop accuracy

1

DPT &

DPM Series

From 1/2 to Full
Scale Load

3σ less than 3% scatter
of target load.

From 1/4 to 1/2 of
Full Scale Load

3σ less than 4% scatter
of target load.

DPS Series

From 1/4 to Full
Scale Load

3σ less than 1.5%
scatter of target load.

Load resolution

Approx. 1/1000 of full scale load value

Load control range

25% -100% of full scale load value

Load judgment range

10% -100% of full scale load value

Distance stop accuracy

1,2

± 0.01mm (-0.0 ~ +0.02mm)

Distance display minimum unit

0.1mm (0.001mm condition limit)

Distance internal control unit

0.001mm

Load cell accuracy

± 1% (0 - full scale)

Load cell linearity

± 0.5% of Full Scale value (maximum)

Press method

Load method / distance method

Ram tip pendant allowable load

1/6 or less of tool maximum load (up to 2kN)
(With brake option)
DPS-101R3-** tool is up to 0.6KN

1) When the press is operated according to FEC specifications.
2) When load is constant.