FEC DSP1500 (SAN3) User Manual

Page 81

Advertising
background image


enFORCE

DSP1500 SAN Unit Operation Manual

PAGE 6-5 (Rev

4)

Chapter 6: System Operation

Data format when the judgment is a REJECT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Cycle Count 

Press 

Number 

Parameter 

Number 

30H 30H 30H 30H 30H 30H

30H

31H

20H

30H

31H

20H

20H 31H 20H 20H

0 0 0 0 0 0 0 1 0 1 1

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Judgment Load 

Judg

ment

Judgment Distance 

Judg

ment 

31H 32H 2EH 33H 34H 48H

20H

31H

32H

33H

2EH

34H

35H 36H 4CH 20H

1 2 . 3 4 H 1 2 3 . 4 5 6 L

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Final Load 

Judg

ment

Final Distance 

Judg

ment

31H 32H 2EH 33H 34H 20H

20H

31H

32H

33H

2EH

34H

35H 36H 20H 20H

1 2 . 3 4 1 2 3 . 4 5 6

49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64

Part Check 1 Distance 

Judg

ment

Part Check 2 Maximum Load 

Judg

ment 

31H 32H 33H 2EH 34H 35H

36H

5AH

20H

31H

32H

2EH

33H 34H 48H 20H

1 2 3 . 4 5 6 Z 1 2 . 3 4 H

65 66 67 68 69 70 71 72 73 74 75 76 77 78

Part Check 3 Maximum Load 

Judg

ment

Judg

ment

Rea 
son 

CR LF

31H 32H 2EH 33H 34H 4CH

20H

20H

58H

20H

20H

20H

0DH 0AH

1 2 . 3 4 L X

Overall Judgment 

 

           Reason for Stop 

"X"(58H):REJECT 
 

"00000001 01 1 12.34H 123.456L 12.34 123.456 123.456Z 12.34H 12.34L X "+CR+LF

When the reject is for Final Load or Final Distance the Judgment Load and Judgment
Distance are also judged.