PAGE 6-44

Chapter 6: System Operation

ƒ

Final Load Low Limit Judgment Disable [ 0 ]

Judgment of a “Low Load” condition at the end of the press cycle will not be reported.
All other judgments will be performed.

ƒ

Final Load Low Limit Judgment Enable [ 1 ]

Judgment of a “Low Load” condition at the end of the press cycle will be reported. All
other judgments will be performed.

ƒ

Final Load Low Limit Judgment Disable + Part 3 Check [ 2 ]

Judgment of a “Low Load” condition at the end of the press cycle will not be reported.
This selection also enables the “Part Check 3” functionality. (See Page 6-36 for Part
Check 3 Explanation)

ƒ

Final Load Low Limit Judgment Enable + Part 3 Check [ 3 ]

Judgment of a “Low Load” condition at the end of the press cycle will be reported. This
selection also enables the “Part Check 3” functionality. (See Page 6-36 for Part Check
3 Explanation)

Because “High Load” conditions have the potential to destroy the parts
and/or press, they are ALWAYS judged.


If a Part 3 Check is set to be performed near the target and the press speed is
set too fast, then the judgment may not be performed until the final distance.
If using Part Check during the Time Controlled Press Method, the Part Check
will not be performed after the press has sensed Time Start Load.

ƒ

Final Load Low Limit Judgment Disable + Band Check [ 4 ]

This selection is only possible if “Band Check” is enabled in the System
Settings.

Judgment of a “Low Load” condition at the end of the press cycle will not be reported.
This selection also enables the “Band Check” setup functionality.

ƒ

Final Load Low Limit Judgment Enable + Band Check [ 5 ]

This selection is only possible if “Band Check” is enabled in the System
Settings.

Judgment of a “Low Load” condition at the end of the press cycle will be reported. This
selection also enables the “Band Check” setup functionality.




ƒ

Positive Load [ 0 ] (Default)

Pressing under a load condition will be performed while the press ram is advancing.

ƒ

Negative Load [ 1 ]

Pulling under a load condition will be performed while the press ram is returning.

This selection is set according to the type of press that has been purchased
and should not be changed.











Judgment Operation

Loading Direction

Н