Load Drop Detection – Point Stop (Method 7)


This Load Control press method is similar to Method 3 (Load Drop Detection) except,
once [19: Load Change] has been detected, the press will stop. The press will attempt
to detect this value until it reaches [14: Target Load]. During the press cycle, checks
are performed for “Interference Check” / “Part Check”, Load and Distance. If any of
these values are compromised, the press will stop and return as programmed.

Final

Judgment is based on the distance of the peak load (DS/PS) prior to where the
decreasing change in press force equals or exceeds [19: Load Change].
**If JUDGMENT OPERATION is set to “1” or “3” final load will also be judged.

(See corresponding sections for Interference Check and Part Check explanations.)



ƒ

[19: Load Change] is a “control” function and is not used for judgment.














Load

Distance

[11] Final Load High Limit

[12] Load Low Limit

[14] Target Load

[39]

Detection

Start Distance

[30]

Final Distance
High Limit

Final Judgment Zone

[32]
Distance

High Limit

Judgment Load (PS)

[13] Load High Limit

(DS)

[19] Load Change

Detection