Chapter 8: Troubleshooting

8.10 Questions & Answers


Q1: Does home position search have to be performed every time the power is turned on?

A1:

Yes.
Home position search may also need to be performed after a catastrophic abnormal has
occurred.


Q2: REJECT was output but the reason in unclear.

A2:

See

“Press Result Display Mode” in Section 6.3.5.

Contents of the REJECT is shown from ‘ 6 ’ to ‘ 9 ’.


Q3: Is it possible to press while jogging in Manual Mode?

A3:

No.

Abnormal 9-8 will occur when 1/6 of the full-scale load is detected.

It is possible to jog using a parameter.
When you want to JOG operate, set the operation finish mode to JOG RETURN and
turn the START signal ON and turn it OFF when you want to stop. It will start from the
present position if it is turned ON again.

ƒ When set to Jog Return Mode, if a load is detected when the START signal goes

off, the load will be released.

ƒ If you do not want the load to be released, set to Keep Load Mode. Also, turn on

the Self Check Off signal before starting again or when returning or an abnormal
will be generated due to a force being present at START.

When the Self Check signal is turned off, the present load is set to
the 0 load value, so be careful. ** It is a possible to destroy the
equipment using this method. **
This method can be used with F type tools, but make sure it is not
overloaded.