FEC DSP1500 (SAN3) User Manual

Page 19

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

PAGE 1-5 (Rev.

4)

Chapter 1: Outline

¾ Electrical Noise Prevention

• SAN units must be located a minimum of 600mm from high transient voltage sources such

as transformers, motor starters, AC inverters and AC contactors. If it cannot be avoided, the
unit must be shielded.

• If high powered devices are used inside the enclosure, they must use a surge suppression

device.

• Make sure that the power supply lines and cables for connecting the unit and tool are not run

together inside the same duct.

¾ Handling and Shipping

• It is critical that

enFORCE

System components are properly handled and shipped in order

to maintain the system’s integrity. Adhere to the following requirements for shipping and
handling:

ƒ Loose

enFORCE

System components must be individually packaged and shipped

in anti-static containers or wrap to prevent damage from electrostatic discharge.

ƒ If the SAN unit is to be shipped in an enclosure, tighten all mounting screws to prevent

the unit from being dislodged.

ƒ Do not package the tool with the weight of the unit resting on the press ram as

damage to the load cell may occur.

ƒ The tool is heavy. Use lifting rings provided when necessary to move the tool.
ƒ Enclosure must be protected with shrink wrap.
ƒ Enclosure and system components should be shipped on an air ride trailer whenever

possible.

ƒ All non-painted metal parts (except the electric motor and connectors) must be

greased or oiled to prevent rust.

ƒ Do not ship or store the system components in environments where the temperature

is out of the 23~131℉ (-5~55℃) range or where the humidity is above 90%.

1.4 Safety Labels

Various labels are used on the SAN Unit and Press Tool to warn of possible harm or injury. These
labels should be taken very seriously. Refer to the following page for label location.






















HIGH VOLTAGE:

Do not touch exposed connector

terminal. May cause electric shock. Disconnect power before

servicing.

DANGER

CAUTION

HOT SURFACE:

Do not touch heatsink.

May cause burn.

Use proper grounding techniques.
May cause electric shock.

DANGER

Do not disassemble
May result in
serious injury

Pinch Point
Watch your hands
Keep away

DANGER

CAUTION

HOT SURFACE

Do not touch

HIGH VOLTAGE

HOT SURFACE

PROPERLY GROUND

Advertising