Enforce – FEC DSP1500 (SAN3) User Manual

Page 52

Advertising
background image

enFORCE

DSP1500 SAN Unit Operation Manual

(Rev. 4)

PAGE 4-12

Chapter 4: System Setup and Wiring

*Allow at least 20ms from the time the desired bank is selected before reading the OUT DATA
signal.

BANK1 BANK0

OUT DATA Signal

Name

Description

OFF OFF

OUT DATA0 SERVO ON

Output when press motor is on (running)

OUT DATA1 HOME SET

Output after home position has been defined.

OUT DATA2 PRESS RET’D

Output when the press is stopped in home position.

OUT DATA3 BUSY

Output while operating.

OUT DATA4 READY

Output when the system is READY to operate.

OUT DATA5 ABNORMAL

Output when an Abnormal condition occurs.

OUT DATA6 ACCEPT

Output when the system has halted without failure.

OUT DATA7 REJECT

Output when the system has halted with failure.

OUT DATA8 ADVANCED

Output when the press has reached target load or distance.

OUT DATA9 ADV / RET POS.

Advance / Return Position Output signal.

OUT DATA10 BANK1

Output echo of BANK Select 1 Input.

OUT DATA11 BANK0

Output echo of BANK Select 0 Input.

OFF ON

OUT DATA0 HOME

RET’D

Output when the press is between Home Position and the
position shown in System Parameter 00-35.

OUT DATA1 BYPASS

Output when the press is in Bypass (switch or input)

OUT DATA2

OUT DATA3 WORK SELECT 4

Output echo of selected Input.

OUT DATA4 WORK SELECT 3
OUT DATA5 WORK SELECT 2
OUT DATA6 WORK SELECT 1
OUT DATA7 WORK SELECT 0
OUT DATA8

OUT DATA9

OUT DATA10 BANK1

Output echo of BANK Select 1 Input.

OUT DATA11 BANK0

Output echo of BANK Select 0 Input.

ON OFF

OUT DATA0 LOAD_LOW

Output on a Low Load Reject.

OUT DATA1 LOAD_HIGH

Output on a High Load Reject.

OUT DATA2 DIS_ LOW

Output on a Low Distance Reject

OUT DATA3 DIS_

HIGH

Output

on

a High Distance Reject

OUT DATA4 CK1_LOW

Output on a Check 1 Low Reject

Hi h Ab

l

Both ON:
Interference Reject

OUT DATA5 CK1_HIGH

Output on a Check 1 High Reject

OUT DATA6 CK2_LOW

Output on a Check 2 Low Reject

OUT DATA7 CK2_HIGH

Output on a Check 2 High Reject.

OUT DATA8 CK3_LOW

Output on a Check 3 Low Reject

OUT DATA9 CK3_HIGH

Output on a Check 3 High Reject.

OUT DATA10 BANK1

Output echo of Bank Select 1 Input.

OUT DATA11 BANK0

Output echo of Bank Select 0 Input.

ON ON

OUT DATA0 ABNSUB-CODE0

Abnormal Sub Code Bit 0 Output

OUT DATA1 ABNSUB-CODE1

Abnormal Sub Code Bit 1 Output

OUT DATA2 ABNSUB-CODE2

Abnormal Sub Code Bit 2 Output

OUT DATA3 ABNSUB-CODE3

Abnormal Sub Code Bit 3 Output

OUT DATA4 ABN-CODE0

Abnormal Code Bit 0 Output

OUT DATA5 ABN-CODE1

Abnormal Code Bit 1 Output

OUT DATA6 ABN-CODE2

Abnormal Code Bit 2 Output

OUT DATA7 ABN-CODE3

Abnormal Code Bit 3 Output

OUT DATA8

OUT DATA9

OUT DATA10 BANK1

Output echo of Bank Select 1 Input

OUT DATA11 BANK0

Output echo of Bank Select 0 Input.





Advertising